USP 4 Flow-through Cell Dissolution

In the world of research there is always the apprehension that in-vitro results may not accurately replicate conditions that occur inside the body. Enter the USP Apparatus 4 and the wide range of new benefits it brings, in particular, as a suitable bridge between in-vitro and in-vivo studies.

Of course, USP 4 is not meant to replace USP 1 or 2 but rather offer new ways to conquer dosage form challenges. It can be used with both small and large tablets, powders, suppositories, implants and stents, and provides unique solutions to determine their dissolation rates. For example, when determining the dissolution rate of pure solid substances with USP 4 compared with USP 1 and 2, a notable difference is elimination of the need for compression as substances are tested in loose powder or granulate form, whereas with USP 1 and 2 compression is necessary (which in-turn can ultimately affect particle size, specific area, etc).

When looking further at USP Apparatus 4 we can break it down into two main modes of operation. That of Open Configuration and that of Closed Configuration. Both have advantages of their own, and we use both at Quinta-Analytica, yet work in slightly different ways. Whereas in the open configuration the flow-through cell apparatus is used as a system where fresh solvent feeds directly from the reservoir and passes constantly through the cell where the dosage form is accommodated; in a closed system on the other-hand it recycles a fixed volume of that medium. Ultimately enabling a wider range of options for the research.

Diving deeper into the open configuration, the reservoir volume is not fixed and can be increased/decreased to ensure that the concentration of the drug is such that it can be detected accurately; a calculation is then done by taking the average concentration which is divided by the number of minutes elapsed and that results in an estimate of the release rate over the time interval. This type of setup is especially useful for drugs which are not readily soluble. The closed configuration on the other hand, follows a different flow; a pump returns the medium via an in-line reservoir (which further allows heating/ stirring/ sampling etc. during the process) and then recycles that to the cell. Calculating the concentration of analyte and the volume in the system, gives the cumulative release result.

Tying everything together, clearly both options have advantages and the versatility of the USP 4 Apparatus, with respect to alteration of flow and the in-vitro/in-vivo correlations of the poorly soluble compounds, demonstrates quite clearly that the method is more reliable, reproducible and discriminating than other systems.

Our partner Sotax has prepared a detailed overview for USP 4, which you can download here.

Would you like to hear more about USP Apparatus 4 and how it can help you? Get in touch with us and we'll be more than happy to discuss your needs.

Posted on

December 16, 2019

Heading

What’s a Rich Text element?

The rich text element allows you to create and format headings, paragraphs, blockquotes, images, and video all in one place instead of having to add and format them individually. Just double-click and easily create content.

Static and dynamic content editing

A rich text element can be used with static or dynamic content. For static content, just drop it into any page and begin editing. For dynamic content, add a rich text field to any collection and then connect a rich text element to that field in the settings panel. Voila!

How to customize formatting for each rich text

Headings, paragraphs, blockquotes, figures, images, and figure captions can all be styled after a class is added to the rich text element using the "When inside of" nested selector system.

Posted on

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Suspendisse varius enim in eros elementum tristique. Duis cursus, mi quis viverra ornare, eros dolor interdum nulla, ut commodo diam libero vitae erat. Aenean faucibus nibh et justo cursus id rutrum lorem imperdiet. Nunc ut sem vitae risus tristique posuere.

in

Text Link

category

related
We're there now! Please visit us at stand 121B56.
We're there now! Please visit us at stand 121B56.
We're at CPhI Worldwide! Visit us at stand 121B56.
Let's Go!